Vertical Autoclave/Steam sterilizers IVA-1600D
Vertical Autoclave/Steam sterilizers IVA-1600D are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Horizontal Autoclave/Steam Sterilizer IHA-2400 basic 180 L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
The IHA-2400 comes with pressure safety interlock device, safety valve, over current and short circuit protection, automatic fault detection, dry burn protection, water level detection, over temperature protection, leakage protection. The benefits of product diversity and flexible options to make the right match and perfect fit for your customer needs The machine has maximum sterilization pressure of 105 and 135°C with overload pressure protection. Provide 6 different exhaust steam speeds can be selected according to the material to be destroyed.Offer large volume water tank, set drainage temperature and the temperature of the sterilizing water. Built-in efficient steam generator, microcomputer temperature control, especially designed for bulk volume and highest flexibility in processing requirement.
Data sheet
Model | IHA-2400 | IHA-2600 |
Capacity | 180L | 280L |
Sterilizing Chamber Size | 500x1000 mm | 600x1000 mm |
Materials | S30408 | |
Sterilizing Working Temperature | 105 to 135 ? | |
Pressure gauge display range | -0.1 to 0.5MPa | |
Safety valve take-off pressure | 0.29 MPa | |
Sterilization Time | 1 to 6000 minutes | |
Drying Time | 0 to 300 minutes | |
Pulsation Times | 1 to 99 times | |
Display | LCD | |
Vacuum | ?-93kpa | |
Installation device | Pressure safety interlock device, safety valve, over current and short circuit protection, automatic fault detection, dry burn protection, water level detection, over temperature protection, leakage protection | |
Annex | 2 stainless steel braided baskets (with casters at the bottom), shelf | |
Options | Item thermometer, printer, item thermometer, water source pressure sensor (optional), trolley | |
H upgrade type (optional) | Upgrade stainless steel to S316L PLC industrial control system to Siemens industrial control system | |
Control | PLC industrial control system | |
Function Mode | Fabric mode Instrument mode Liquid mode BD experiment mode Vacuum test mode Custom program mode | |
Certification | - | - |
Power Consumption | 1600 W | |
Dimension | 800x1450x1500 mm | 800x1450x1500 mm |
Net Weight | 650 kg | 720 kg |
Electrical Requirement | - | - |
Catalogue No. | 5807505-04 | 5807510-04 |
| Model | IHA-2400 | IHA-2600 |
| Capacity | 180L | 280L |
| Sterilizing Chamber Size | 500x1000 mm | 600x1000 mm |
| Materials | S30408 | |
| Sterilizing Working Temperature | 105 to 135 ? | |
| Pressure gauge display range | -0.1 to 0.5MPa | |
| Safety valve take-off pressure | 0.29 MPa | |
| Sterilization Time | 1 to 6000 minutes | |
| Drying Time | 0 to 300 minutes | |
| Pulsation Times | 1 to 99 times | |
| Display | LCD | |
| Vacuum | ?-93kpa | |
| Installation device | Pressure safety interlock device, safety valve, over current and short circuit protection, automatic fault detection, dry burn protection, water level detection, over temperature protection, leakage protection | |
| Annex | 2 stainless steel braided baskets (with casters at the bottom), shelf | |
| Options | Item thermometer, printer, item thermometer, water source pressure sensor (optional), trolley | |
| H upgrade type (optional) | Upgrade stainless steel to S316L PLC industrial control system to Siemens industrial control system | |
| Control | PLC industrial control system | |
| Function Mode | Fabric mode Instrument mode Liquid mode BD experiment mode Vacuum test mode Custom program mode | |
| Certification | - | - |
| Power Consumption | 1600 W | |
| Dimension | 800x1450x1500 mm | 800x1450x1500 mm |
| Net Weight | 650 kg | 720 kg |
| Electrical Requirement | - | - |
| Catalogue No. | 5807505-04 | 5807510-04 |
Vertical Autoclave/Steam sterilizers IVA-1600D are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-2600 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Vertical Autoclave/Steam sterilizers IVA-3100 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
The ITA-216 front loading ‘Benchtop’ autoclave range is available in four sizes. These units require no plumbing, and only a standard single phase power supply. A 5.7-inch colour touchscreen with integrated USB data port. Electro polished stainless steel chamber.
Touch Screen Horizontal Autoclave/Steam Sterilizer IHA-3050 basic 50L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Single Door Horizontal Autoclave/Steam Sterilizer IHA-8200S basic 250L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
The ITA-212 front loading ‘Benchtop’ autoclave range is available in four sizes. These units require no plumbing, and only a standard single phase power supply. A 5.7-inch colour touchscreen with integrated USB data port. Electro polished stainless steel chamber.
Pulse Vacuum Vertical Autoclave/Steam sterilizers IVA-5100 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply. Equipped with an effective air-cooling system for liquid sterilization.
Touch Screen Pulse Vacuum Vertical Autoclave/Steam sterilizers IVA-6020 designed with elevating type door, which is more convenient to place and fetch the objects from the autoclave. Build in 7-inch capacitive touch screen, fully automatically controlled, easy to operate.
Vertical Autoclave/Steam sterilizers IVA-1400 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply.
Single Door Horizontal Autoclave/Steam Sterilizer IHA-8200S basic 250L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Pulse Vacuum Vertical Autoclave/Steam sterilizers IVA-5050 are floor standing self-contained sterilizer units that require no plumbing and operate from a standard single-phase power supply. Equipped with an effective air-cooling system for liquid sterilization.
Horizontal Autoclave/Steam Sterilizer IHA-4100 basic 150L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Horizontal Autoclave/Steam Sterilizer IHA-4200 basic 200L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.
Benchtop Autoclave/Steam Sterilisers ITA-745 provide the broadest range of steam sterilizers and has a solution available to maximize department productivity and optimize workflow. It can be used to Inactivated AIDS (HV), hepatitis B (HBV) mad cow virus and spores.
Pulse Vacuum Large Horizontal Autoclave/Steam Sterilizer IHA-6300 basic 600L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use.